Moyes Delta Gliders

glass-tip-holder

We have sighted a few cases where the concentric ring has broken free from its glued position and moved closer to the eccentric ring. This changes the angle of the glass tip and may produce a turn in the glider.

To fix this situation, ensure that the concentric ring is aligned hard against the clevis pin. To keep the concentric pin in place, some glue or Silastic can be applied to the ring.

We have adjusted our manufacturing procedures to resolve this issue.