Category: Technical Advisory
In our ongoing commitment to safety, we want to address an issue regarding the nyloc (locking) nut loosening on the top fittings on our gliders with Zoom uprights.
Correct: Zoom upright top fitting with thread exposed.
Incorrect: Zoom upright top fitting with NO thread exposed
Category: Technical Advisory
To install the Hang Loop(HL)
Category: Technical Advisory
Applies from: 17th August, 2015
Applies to: Any Moyes glider using round uprights.
Inspection: Whenever an upright is broken or bent it may cause damage to the top and bottom upright fittings, these parts should be inspected closely and replaced at any sign of wear or damage.
Service Requirement: Replace bottom upright fitting after 300 hours or if wire slot widens to greater than 4.8 mm.
It has been bought to our attention of a potential problem of the bottom upright fitting on gliders with round uprights.
The wear has occurred on the slot where the ball swage fits into.
The photo shows a fitting from a glider with 600+ hours airtime where the slot has been worn and widened.
The photo shows a broken fitting from a training glider.
It is now mandatory to replace the fitting
when the opening exceeds 4.8mm or after 300 hours airtime.
Category: Technical Advisory
Please find attached the expansion of the recall of the austrialpin DELTA carabiners.
Category: Technical Advisory
A potential defect have been advised by the supplier of the ‘Delta’ carabiner that we use on all of our harnesses.
From our records we have identified to have purchased the ‘Delta’ carabiner dating from 26th February, 2013 to date.
If you purchased a harness or carabiner from Moyes from between 1st January, 2013 to 14th October, 2014 you need to carefully check the carabiner for the batch number.
"For the safety of all customers AustriAlpin is issuing an immediate voluntary recall of certain batches of the Austrialpin DELTA carabiner delivered after October 2012. If you own a Austrialpin DELTA carabiner that was purchased after October 2012.
Please read this notice carefully and follow the instructions. (see Austrialpin_recall_DELTA_carabiner.pdf)
Affected are DELTA carabiners, article number FD00A with the batch numbers 00001 and Ø0001"